100% In-House — Canby, Oregon

In-House Engineering Excellence

MRX handles every phase of industrial fabrication in-house — CFD thermal modeling, ASME BPVC 2026 pressure vessel design, UL-Listed intrinsically safe controls, precision stainless steel finishing, and full turnkey system commissioning — all at our Canby, Oregon facility with zero outsourcing.

Six disciplines. One facility. One team accountable from concept to commissioning.

Discuss Your Project with Our Engineers

What We Do Best

What Are MRX Manufacturing's Core Capabilities?

MRX provides six integrated engineering and fabrication capabilities — from CFD thermal analysis and ASME vessel fabrication to UL-Listed controls and turnkey commissioning — all performed in-house in Canby, Oregon.

Zero outsourcing. Full traceability. Single-point accountability.

CapabilityStandards & CertificationsKey Applications
CFD & FEA EngineeringSolidWorks, ANSYSThermal systems, cooling loops
ASME Vessel FabricationBPVC 2026, U/UM StampsPressure vessels, tanks
UL-Listed ControlsUL 508A, UL 698AHazardous environments, data centers
Surface FinishingFDA, 3-A, ASME BPEPharma, food & dairy
Turnkey IntegrationNEC, NFPAComplete process systems
FAT & CommissioningHydrostatic, pneumaticAll project types

All capabilities performed in-house at our Canby, Oregon facility

In-House Design & CFD Thermodynamics Modeling

Advanced computational simulation that predicts heat transfer, fluid flow, and structural behavior before fabrication begins.

MRX engineers use in-house CFD thermodynamics modeling to optimize every thermal system we build — from data center liquid cooling loops to pharmaceutical process heating. Finite element analysis (FEA) validates structural integrity under real-world operating pressures and temperatures, eliminating costly redesigns and ensuring first-pass success.

  • 3D parametric modeling with SolidWorks and ANSYS
  • CFD thermal and fluid flow simulation for cooling systems
  • FEA stress, fatigue, and buckling analysis per ASME BPVC
  • Complete P&ID, GA, and fabrication drawing packages
See our data center cooling systems

ASME BPVC 2026 Code Expertise & Pressure Vessel Fabrication

Pressure vessel engineering and fabrication fully compliant with the latest 2025 edition of the ASME Boiler and Pressure Vessel Code, Section VIII.

The 2026 ASME BPVC edition introduces updated common design rules, revised flange equations under Appendix 2, and enhanced fatigue analysis requirements. MRX engineers are current on every update. Our Canby, Oregon facility holds ASME U and UM stamps, and every vessel is inspected by a National Board-commissioned Authorized Inspector before shipment.

  • U and UM code stamps — 2025 edition compliant
  • Revised flange and nozzle calculations per latest Appendix 2
  • Full radiography (RT), ultrasonic (UT), and hydrostatic testing
  • Carbon steel, 304/316L stainless, Hastelloy, and exotic alloys
Browse our pressure vessel products

UL-Listed Electrical & Intrinsically Safe Controls

In-house design and fabrication of UL-Listed control panels and intrinsically safe electrical systems for hazardous and high-density computing environments.

MRX operates a full UL-Listed electrical shop in Canby, Oregon — one of the few industrial fabricators in the Pacific Northwest with this capability in-house. We design, wire, program, and UL-List every panel ourselves: no third-party panel shops, no hand-offs, no accountability gaps. Our intrinsically safe controls are deployed in Class I Division 1 and 2 hazardous locations across regulated industries and high-density data center cooling systems.

  • UL 508A industrial control panels and UL 698A hazardous location panels
  • Intrinsically safe barrier designs for Class I Div 1 & 2 areas
  • PLC programming, HMI development, VFD integration, and SCADA
  • Full electrical documentation, loop sheets, and as-built packages
See controls for data center cooling

Precision Stainless Steel Fabrication & Surface Finishes

Pharmaceutical-grade and food-grade stainless steel fabrication with validated surface finishes for regulated manufacturing environments.

MRX delivers electropolished, mechanically polished, and passivated stainless steel surfaces that meet the strictest requirements in pharmaceutical, biotech, food, and dairy manufacturing. Our in-house finishing capabilities include riboflavin testing to verify CIP coverage, ensuring every vessel and component passes validation on the first attempt. Sanitary fabrication is treated as a functional requirement at MRX — not a cosmetic step. Surface condition, weld execution, and transition geometry each affect how equipment cleans, how long it lasts, and how confidently it can be operated in validated environments.

  • Electropolished to 15-25 Ra (0.6-1.0 µm) surface finish
  • Mechanical polishing to 180-grit mirror finish
  • Passivation, derouging, and riboflavin testing services
  • FDA, 3-A SSI, USDA, and ASME BPE compliant finishes
View sanitary mixing tanks and vessels

Full Turnkey System Integration

Complete process system assembly — vessels, heat exchangers, pump carts, chillers, power distribution, and controls — delivered ready to operate.

Turnkey means MRX handles every subsystem under one roof: ASME vessels, process piping, heat exchangers, pump skids, chillers, cooling towers, UL-Listed control panels, power distribution, and utility connections. This eliminates multi-vendor coordination, reduces lead time, and gives you a single engineering team accountable from concept through commissioning.

  • Vessels, process piping, and structural steel fabrication
  • Pump carts, valve manifolds, and instrumentation packages
  • Chillers, cooling towers, and plate heat exchangers
  • Power distribution, MCC, and utility tie-in coordination
Explore our complete product line

Factory Acceptance Testing & Global Installation Support

Rigorous in-house FAT protocols and worldwide field service for installation, startup, commissioning, and operator training.

Every MRX system undergoes comprehensive factory acceptance testing at our Canby, Oregon facility before crating and shipment. FAT protocols include hydrostatic and pneumatic pressure testing, leak detection, controls functional verification, and full documentation review. Our field service engineers then supervise rigging, installation, startup, and performance validation on-site — anywhere in the world.

  • Written FAT protocols with client witness invitation
  • Hydrostatic, pneumatic, and helium leak testing
  • On-site installation supervision and startup commissioning
  • Operator training, O&M manuals, and as-built documentation
Certifications & Compliance

What Certifications Does MRX Hold?

MRX Manufacturing holds a comprehensive portfolio of certifications and code stamps — covering pressure vessel fabrication, electrical safety, quality management, sanitary standards, and international compliance.

Pressure Vessel & Boiler

  • ASME Section VIII, Div. 1 "U" Stamp
  • ASME Section VIII, Div. 1 "UM" Stamp (Miniature Vessels)
  • ASME BPE (Bioprocessing Equipment)
  • 2026 ASME BPVC Edition — Full Compliance
  • National Board "R" Repair Stamp
  • National Board Vessel Registration (NB Mark)

Electrical & Controls

  • UL 508A Industrial Control Panels
  • UL 698A Intrinsically Safe Systems
  • NEC & NFPA 70 Compliant Wiring
  • NFPA 79 Industrial Machinery Standards
  • CSA / C-UL Recognized Components
  • IEC 61508 Functional Safety (SIL-rated)

Quality & Management

  • AWS D1.1 / D1.6 Structural Welding
  • AWS D17.1 Aerospace Welding (Qualified)
  • ASME Section IX Welding Procedures (WPS/PQR)
  • OSHA VPP Safety Compliant Facility
  • Confined Space Entry (CSE) Certified

Sanitary & Food Safety

  • 3-A Sanitary Standards (3-A SSI)
  • FDA 21 CFR Part 110/117 Compliance
  • USDA Accepted Equipment Design
  • cGMP Pharmaceutical Manufacturing
  • USP Class VI Elastomer Compatibility
  • EHEDG Hygienic Design Principles

Industry-Specific Codes

  • API-650 Welded Tanks for Oil Storage
  • API-620 Large Low-Pressure Storage Tanks
  • ASME B31.3 Process Piping
  • TEMA Heat Exchanger Standards
  • NBBI (National Board of Boiler Inspectors)
  • ANSI/ISA-84 Safety Instrumented Systems

International & Regional

  • CE/PED (Pressure Equipment Directive — Europe)
  • CRN (Canadian Registration Number)
  • NR-13 (Brazil Regulatory Standard)
  • MOM (Ministry of Manpower — Singapore)
  • AS 1210 (Australian Pressure Vessels)
  • DOSH (Malaysia — Dept. of Safety & Health)

Certifications maintained and audited annually. Documentation available upon request for all applicable standards.

Materials of Construction

What Materials Does MRX Work With?

MRX fabricates with an extensive range of stainless steels, high-nickel alloys, reactive metals, and specialty elastomers — matched to the corrosion resistance, temperature rating, and regulatory requirements of your specific application.

Stainless Steels

  • 304 / 304L Austenitic Stainless
  • 316 / 316L Molybdenum-bearing
  • 317L High Molybdenum
  • 321 Titanium-stabilized
  • 347 Niobium-stabilized
  • Duplex 2205 (UNS S31803)
  • Super Duplex 2507
  • 254 SMO (UNS S31254)

High-Nickel & Specialty Alloys

  • Alloy 20 (Carpenter 20)
  • Hastelloy C-22 / C-276
  • Inconel 600, 601, 625
  • Incoloy 800, 825
  • Alloy 904L
  • AL-6XN (UNS N08367)
  • Monel 400 / K-500
  • Alloy 200 / 201 (Pure Nickel)

Reactive Metals & Carbon Steels

  • Titanium Grades 1, 2, 5, 7, and 12
  • Zirconium 702 / 705
  • Tantalum (corrosion-critical apps)
  • Carbon Steel SA-516 Gr. 70
  • Chrome-Moly SA-387 (1¼Cr-½Mo)
  • Low-Temp Carbon SA-350 LF2
  • Clad & Explosion-bonded Plates
  • Lined vessels (PTFE, glass, rubber)

Surface Finishes

  • Mill finish (#1, #2B, #2D)
  • Mechanical polish: 180-grit to mirror (#4, #7, #8)
  • Electropolished: 15 Ra (0.6 µm) to 10 Ra (0.4 µm) and lower
  • Passivation per ASTM A967 / A380
  • Derouging and chemical cleaning
  • Riboflavin (Vitamin B2) CIP coverage testing
  • Custom Ra specifications to customer requirement

Elastomers & Gasket Materials

  • White Silicone (FDA & USP Class VI)
  • Black EPDM (FDA compliant)
  • Viton® (FKM) — chemical resistant
  • PTFE / Teflon® envelope gaskets
  • Kalrez® (FFKM) — extreme chemical/temperature
  • Buna-N / Nitrile (NBR)
  • Aflas® (TFE/Propylene) — high-temp/chemical service

Material certifications (MTRs) provided with every order. Specialty alloys sourced from qualified domestic and international mills.

From Concept to Commissioning

How Does the MRX Engineering Process Work?

MRX follows a five-phase engineering process — from requirements gathering and CFD analysis through ASME-compliant fabrication, UL-Listed controls integration, factory acceptance testing, and on-site commissioning — to deliver turnkey systems ready to operate on day one.

Every phase happens under one roof in Canby, Oregon.

Step 01

Requirements Gathering & CFD Thermal Analysis

We capture your process requirements — flow rates, temperatures, pressures, fluid properties, and materials of construction — then build a complete CFD thermal model to validate heat transfer and fluid dynamics.

Step 02

Custom Design with 2026 ASME BPVC Compliance

Our engineers produce full 3D models, P&IDs, and fabrication drawings. Every pressure-containing component is designed to the 2025 edition of ASME BPVC Section VIII and verified by our Authorized Inspector.

Step 03

In-House Fabrication, Welding & Controls Integration

Steel is cut, formed, welded, and finished at our Canby facility while our electrical shop simultaneously builds and UL-Lists the control panels, wiring harnesses, and safety interlocks.

Step 04

Integrated System Testing & Factory Acceptance Testing

The complete system is assembled, plumbed, wired, and tested as a unit. Full FAT — hydrostatic pressure, leak detection, controls functional, and safety verification — before it leaves our floor.

Step 05

Delivery, Installation & Ongoing Support

MRX coordinates logistics and rigging, supervises field installation, commissions the system, validates performance against design specs, and trains your operators on-site.

Free Planning Tool

Is Your Facility Ready for This System?

Use the MRX Facility Readiness Planner to assess space, utilities, shipping access, and commissioning readiness in five short steps — before your project begins.

The In-House Advantage

Why Does In-House Engineering Matter for Industrial Fabrication?

In-house engineering eliminates multi-vendor coordination delays, reduces lead times, and gives you a single team accountable for design, fabrication, controls, testing, and commissioning — which is especially critical for complex data center cooling and regulated process equipment.

Quality goes up, timelines shrink, and finger-pointing disappears.

Faster Lead Times with Full Accountability

Design, fabrication, and controls happen in parallel under one roof. No waiting on third-party vendors or chasing subcontractor schedules.

Zero Outsourcing Risk

Every weld, every wire, every line of PLC code is produced by MRX employees. Full traceability, full quality control, full accountability. That level of control — from material selection through commissioning — is what enables long-term reliability: equipment that performs not just at delivery, but throughout its service life.

Seamless Complex System Integration

Data center cooling systems and regulated process equipment require tight coordination across disciplines. In-house integration eliminates interface gaps.

Superior Quality from Concept to Commissioning

ASME, UL, NEC, and NFPA compliance is verified internally at every stage — never delegated to subcontractors who may cut corners.

Key Takeaways — MRX Capabilities

  • All engineering, fabrication, surface finishing, controls, and testing happen in-house at MRX's Canby, Oregon facility — zero outsourcing.
  • CFD and FEA modeling validate thermal and structural performance before any material is cut, reducing costly redesigns.
  • ASME BPVC 2026 compliance with U/UM stamps on every coded vessel; UL 508A and UL 698A listed control panels for hazardous environments.
  • Turnkey delivery includes factory acceptance testing, crating, rigging, field installation, and full commissioning.
  • 11+ years serving pharmaceutical, food & dairy, biotech, energy, and data center industries.
MRX controls and automation facility floor

Controls & Automation Intelligence

What Makes MRX Controls Smarter Than the Competition?

MRX doesn't bolt on off-the-shelf panels — we design, wire, program, and commission every control system in-house. From intrinsically safe hazardous-area enclosures to AI-assisted process automation, our engineers deliver systems built for 24/7/365 autonomous operation with zero tolerance for downtime.

MRX HMI touchscreen control panel with live process data
MRX in-house UL 508A control panel wiring and assembly
UL 508A Listed Panels
UL 698A Hazardous Areas
100% In-House Wiring
Factory Acceptance Testing

AI-Assisted Process Intelligence

Embedded ML algorithms monitor sensor arrays in real time, detect deviation patterns before they become failures, and auto-adjust set points — keeping your process running at peak efficiency around the clock.

24/7/365 Autonomous Operation

MRX control architectures are designed for lights-out operation. Redundant PLC loops, watchdog timers, and fail-safe interlocks ensure your system runs autonomously without operator intervention.

Auto-Reporting & Predictive Trend Logging

Every system ships with automatic report generation, configurable trend logs, and predictive maintenance dashboards — so your maintenance team sees problems weeks before they surface.

Intrinsically Safe & Hazardous-Area Certified

UL-Listed intrinsically safe controls for Class I/II/III Division 1 & 2 environments. Every panel is engineered, documented, and stamped for the harshest industrial locations.

Cybersecure SCADA Integration

Network-isolated SCADA and HMI architectures with role-based access, encrypted historian links, and OT-network segmentation — meeting NIST 800-82 guidelines for industrial control security.

100%

In-House Panel Build & Wiring

24/7

Autonomous Operation Ready

UL 508A

Listed Control Panels

Zero

Third-Party Controls Vendors

Ready to Partner with True Engineering Experts?

Let our Canby, Oregon team design your next ASME-compliant pressure vessel, UL-Listed control system, or turnkey data center cooling solution — engineered and built under one roof.

Oregon Engineered • ASME BPVC 2026 Compliant • UL-Listed Intrinsically Safe Controls